Westermo IDW-90 AT User Manual

Page 18

Advertising
background image

18

6620-3200

<min_tx_rate>   Numeric values which specify the lowest (<min_tx_rate>) and  

        and 

highest (<max_tx_rate>) rate at which the modem may establish a  

<max_tx_rate>   transmit connection. Non-zero values for this subparameter are 

decimal encoded, in units of bit/s. The possible values for each 
modulation are listed in Table 1. 
Actual values will be limited to possible values corresponding to 
the entered <carrier> and fall-back <carrier> as determined during 
operation. (default = lowest (<min_tx_rate>) and highest (<max_
tx_rate>
) rate supported by the selected carrier.)

Reporting Current or Selected Values

Command: 

!+MS?

Response: 

 +MS:  <carrier>, <automode>, <min_tx_rate>, <max_tx_rate>, <min_

rx_rate>, <max_rx_rate>

Note:- The current active settings are reported under control of the !+MR  

parameter.

Example:   !+MS=V90, 1, 300,  

This example uses default values, allowing  

33 600, 300, 33 600 

maximum system flexibility to determine  

 optimal receive and transmit rates during  
operation.

Reporting Supported Range of Parameter Values

Command: 

!+MS=?

Response: 

 +MS: (<carrier> range), (<automode> range), (<min_tx_rate> range), 
(<max_tx_rate> range), (<min_rx_rate> range), (<max_rx_rate>
range)

Example: 

 +MS: (B103, B212, V21, V22, V22B, V23C, V32, V32B, V34), (0,1),  
(300-33 600), (300-33 600)

Advertising