6620-3200

bodit – BOD increase timer

bodit=<incrTime>   Sets the time in seconds the bit-rate has to exceed the increase 

value before the second B-channel is connected (default=30)

boddv – BOD decrease value

boddv=<decrValue>  Sets the bit-rate in kbit/s at which  the second B channel is  

disconnected (default=40).

boddt – BOD decrease timer

boddt=<incrTime>   Sets the time in seconds the bit-rate has to be below the 

increase value before the second B-channel is disconnected 
(default=30)

br – Baudrate asynchronous
Selection of the asynchronous baudrate for the DTE interface

0: Autobauding, (automatic local bit rate adaption) (default)

1: 1 200 bit/s

2: 2 400 bit/s

3: 4 800 bit/s

4: 9 600 bit/s

5: 19 200 bit/s

6: 38 400 bit/s

7: 57 600 bit/s

8: 115 200 bit/s

Note:  Autobauding (br = 0) is available for AT command set only. 

brn – Line baudrate asynchronous V.110
Selection of the asynchronous baudrate for V.110 line (B channel)

0: Line baudrate equals local baudrate (default)

1: 1 200 bit/s

2: 2 400 bit/s

3: 4 800 bit/s

4: 9 600 bit/s

5: 19 200 bit/s

6: 38 400 bit/s

bsize – Frame length
Maximum length of a data frame (default 2048)  
Note! changing the B-channel protocol will affect the bsize parameter.  
This setting is valid for both received and transmitted data frames.

prot=X.25-B  128

prot=X.31-D  128

prot=X.75 

2048

values: 

32 .. 2048