Westermo IDW-90 AT User Manual

Page 96

Advertising
background image

96

6620-3200

11. Example Modem Response and Usage

Table 18  Completed Data Call, with some errors and rate retrain  

during the call

Modem Response line Description 

Description

DIAG <2A4D3263 0=09>

This is version 0.9

DIAG <2A4D3263 1=06 2=0 3=0>

 Data Answer signal detected; Data only; 
Character async

DIAG <2A4D3263 5=“C14513902A” 6=“A145”>

 V.8 Call Menu indicates: V.8 Joint  
Menu selects:

DIAG <2A4D3263 10=1F 11=0C 12=52>

 Receive level = -31 dBm; transmit level =  
–12 dBm; noise level = -82 dBm

DIAG <2A4D3263 14=03 15=05 16=10> 

 Far end echo delay in milliseconds;  
Far end echo loss in dB; Near end echo 
loss = 16 dB

DIAG <2A4D3263 20=C 22=780 24=0C80 26=79E0>   Transmitter: V.34 training completed; V.34 

carrier frequency = 1920; V.34 symbol rate 
= 3 200; initial transmit rate is 31 200 bit/s

DIAG <2A4D3263 30=00 31=03 32=01 33=01>

 No carrier loss events, 3 carrier rate  
renegotiations attempted; 1 carrier retrain 
requested; 1 carrier retrain granted

DIAG <2A4D3263 40=1 41=100>

 LAPM negotiation completed; 
frame size = 256

DIAG <2A4D3263 42=0 43=0>

No error control timeout or link NAKs

DIAG <2A4D3263 44=1 45=400>

 V.42bis data compression used;  
dictionary size = 1024

DIAG <2A4D3263 50=2 51=2>

 Hardware transmit and receive  
flow control

DIAG <2A4D3263 52=343CC 54=0>

 213964 DTE characters transmitted,  
w/o underrun

DIAG <2A4D3263 53=7230E6 55=47>

 7483622 DTE characters received,  
71 characters lost due to receive data 
overrun

DIAG <2A4D3263 56=29D 58=0001>

 597 (decimal) frames transmitted, 
with 1 frame error

DIAG <2A4D3263 58=2A4B 59=0004>

 10827 (decimal) frames received, 
with 4 frame errors

DIAG <2A4D3263 60=51>

Local PC initiated hangup

Advertising