6620-3200

catab – Automatic call table
With this command the priority table of automatic DTR and TxD calling number is  
set-up.
The IDW-90 will call the numbers defined in order from catab1 to catab3 until a con-
nection is established. The character # is used as prefix to signal that the call shall use an 
analogue connection.

catabx 

nn  set entry number x to receiver number nn.

catabx 

- 

clear entry number x

catabx 

show entry number x

catab 

show all entries

Maximum number of entries = 3
Maximum length of  number = 20 digits.

In example below entry 1 tells IDW-90 to make a call using the analogue modem, while 
entry 2 and 3 making ISDN –ISDN connections.

Example:

catab1 #00461661200

catab2 004616480250

catab3 0123987652

cato – Call timeout to abort
Time to abort a call if not successfully connected after n seconds.

n = 3..255, (default 15 s).

capa – Call pause
Automatic call: set a call pause for n seconds before next call attempt.

n = 0 .. 255, n=0 no call retry, (default 3s).

catry – Calls retry
Automatic call: max. no of tries of every number entry in catab.

n = 1 .. 255 (default 1)

ccts – CTS control
CTS control

0: CTS follows RTS

1: CTS always ON (default)

2: CTS follows DTR

See also 4.3 Serial status lines

cdcd – DCD control
DCD control

0: DCD always ON

1: DCD indicates a connection (default)

2: DCD follows DTR

3: DCD indicates link level established (X.31-D only)

See also 4.3 Serial status lines