ARM Electronics MP13DVPDN User Manual

Page 42

Advertising
background image

41

Motion Detection Setting
Users could adjust various parameters of Motion Detection in this section.

• Sampling pixel interval [1-100]:

The default value is 10, which means system will take one sampling
pixel for every 10 pixel.

• Detection level [1-100]:

The default level is 10. The item is to set detection level for each
sampling pixel; the smaller the value, the more sensitive it is.

• Sensitivity level [1-100]:

The default level is 80, which means if 20% or more sampling pixels are
detected differently, system will detect motion. The bigger the value, the
more sensitive it is. Meanwhile, when the value is bigger, the red
horizontal line in the motion indication window will be lower accordingly.

• Time interval (sec) [0-7200]:

The default interval is 10. The value is the interval between each
detected motion.

Action (Multi-option)

The Administrator can specify alarm actions that will take when motion is
detected. All options are listed as follows:

Enable Alarm Output

Select the item to enable alarm relay output.

Send Alarm Message by FTP/E-Mail

The Administrator can select whether to send an alarm message by
FTP and/or E-Mail when motion is detected.

Upload Image by FTP

Select this item, and the Administrator can assign a FTP site and
configure various parameters as shown in the figure below. When
motion is detected, event images will be uploaded to the appointed FTP
site.

Advertising