Figure 6 – Layout of Switches

2.3 Setting Dome Camera Termination

The device which is connected at end of line, whether it be a dome camera or keyboard
controller, must have the cable for communication terminated by setting the appropriate DIP
switch. Without proper termination, there is potential for control signal errors. Total length of the
cable for communication should not exceed 4000ft (1.2km).

SW1

o

n

SW1

SW1-1 SW1-2

Terminated

ON ON

Not terminated

OFF OFF

Figure 7 – Setting Dome Camera Termination










2.4 Fail-safe Network

When you control the dome by the other device not own keyboard, some error may be existed in
the serial communication. The reason is caused by the other device without the fail-safe network.