Lasting high relative humidity can cause poor insulation, electricity creepage, mechanical property

change of materials, and metal corrosion.

Lasting low relative humidity can cause washer contraction and ESD and bring problems including
loose captive screws and circuit failure.

High temperature can accelerate aging of insulation materials and significantly lower the reliability
and lifespan of the switch.

Cleanliness

Dust buildup on the chassis might result in electrostatic adsorption, which causes poor contact of metal

components and contact points, especially when indoor relative humidity is low. In the worst case,

electrostatic adsorption can cause communication failure.

Table 1 Dust concentration limit in the equipment room

Substance

Concentration limit (particles/m³)

Dust

≤ 3 x 10

4

(no visible dust on the tabletop over three days)

NOTE:

Dust diameter ≥ 5 μm

The equipment room must also meet limits on salts, acids, and sulfides to eliminate corrosion and

premature aging of components, as shown in

Table 2

.

Table 2 Harmful gas limits in the equipment room

Gas

Maximum concentration (mg/m

3

)

SO

2

0.2

H

2

S 0.006

NH

3

0.05

Cl

2

0.01

EMI

All electromagnetic interference (EMI) sources, from outside or inside of the switch and application

system, adversely affect the switch in the following ways:

A conduction pattern of capacitance coupling.

Inductance coupling.

Electromagnetic wave radiation.

Common impedance (including the grounding system) coupling.

To prevent EMI, use the following guidelines:

If AC power is used, use a single-phase three-wire power receptacle with protection earth (PE) to
filter interference from the power grid.

Keep the switch far away from radio transmitting stations, radar stations, and high-frequency

devices to make sure the EMI levels do not exceed the compliant range.

Use electromagnetic shielding when necessary. For example, use shielded interface cables.