Bpdu tunneling for pvst configuration example, Network requirements – H3C Technologies H3C WX5500E Series Access Controllers User Manual

Page 118

Advertising
background image

107

[PE1] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0

# Create VLAN 2 and assign GigabitEthernet 1/0/1 to VLAN 2.

[PE1] vlan 2

[PE1-vlan2] quit

[PE1] interface gigabitethernet 1/0/1

[PE1-GigabitEthernet1/0/1] port access vlan 2

# Disable STP on GigabitEthernet 1/0/1, and then enable BPDU tunneling for STP on it.

[PE1-GigabitEthernet1/0/1] undo stp enable

[PE1-GigabitEthernet1/0/1] bpdu-tunnel dot1q stp

2.

Configure PE 2:
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.

<PE2> system-view

[PE2] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0

# Create VLAN 2 and assign GigabitEthernet 1/0/2 to VLAN 2.

[PE2] vlan 2

[PE2-vlan2] quit

[PE2] interface gigabitethernet 1/0/2

[PE2-GigabitEthernet1/0/2] port access vlan 2

# Disable STP on GigabitEthernet 1/0/2, and then enable BPDU tunneling for STP on it.

[PE2-GigabitEthernet1/0/2] undo stp enable

[PE2-GigabitEthernet1/0/2] bpdu-tunnel dot1q stp

BPDU tunneling for PVST configuration example

Network requirements

As shown in

Figure 31

:

CE 1 and CE 2 are edge devices on the geographically dispersed network of User A. PE 1 and PE
2 are edge devices on the service provider network.

All ports that connect service provider devices and customer devices and those that interconnect
service provider devices are trunk ports and allow packets of any VLAN to pass through.

PVST is enabled for VLANs 1 through 4094 on User As network.

Configure BPDU tunneling for PVST, so that CE 1 and CE 2 implement consistent PVST calculation across
the service provider network, and the destination multicast MAC address carried in BPDUs is

0x0100-0CCD-CDD0.