Configuration procedure – H3C Technologies H3C WX5500E Series Access Controllers User Manual

Page 155

Advertising
background image

144

Figure 43 Network diagram

Configuration procedure

1.

Configure Device B:
# Configure VLAN 5 and VLAN 10 as isolate-user-VLANs.

<DeviceB> system-view

[DeviceB] vlan 5

[DeviceB-vlan5] isolate-user-vlan enable

[DeviceB-vlan5] quit

[DeviceB] vlan 10

[DeviceB-vlan10] isolate-user-vlan enable

[DeviceB-vlan10] quit

# Create VLANs 2, 3, 6, and 8.

[DeviceB] vlan 2 to 3

[DeviceB] vlan 6

[DeviceB-vlan6] quit

[DeviceB] vlan 8

[DeviceB-vlan8] quit

# Associate secondary VLANs 2 and 3 with isolate-user-VLAN 5.

[DeviceB] isolate-user-vlan 5 secondary 2 to 3

# Associate secondary VLANs 6 and 8 with isolate-user-VLAN 10.

[DeviceB] isolate-user-vlan 10 secondary 6 8

# Configure the uplink port GigabitEthernet 1/0/1 to operate in promiscuous mode in VLANs 5
and 10.

[DeviceB] interface gigabitethernet 1/0/1

[DeviceB-GigabitEthernet1/0/1] port isolate-user-vlan 5 10 trunk promiscuous

[DeviceB-GigabitEthernet1/0/1] quit

# Assign the downlink port GigabitEthernet 1/0/2 to VLAN 2, and configure the port to operate
in host mode in VLAN 2. Assign the downlink port GigabitEthernet 1/0/3 to VLAN 3, and

configure the port to operate in host mode in VLAN 3.

[DeviceB] interface gigabitethernet 1/0/2

G

E

1

/0

/3

G

E

1

/0

/6

Advertising