<H3C> display environment

System Temperature information (degree centigrade):

--------------------------------------------------------------------------------

---------

Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit Shutdown-U

pperLimit

hotspot 1 24 0 70 NA NA

hotspot 2 53 0 80 NA NA

Table 13 Command output

Field Description

Sensor

Temperature sensor.
Hotspot indicates a hot-spot temperature sensor.

Temperature Current

temperature

LowerLlimit

Lower limit of temperature

Warning-UpperLimit

Warning temperature threshold.

Alarm-UpperLimit

Alarm temperature threshold.

Shutdown-UpperLimit

Shut-down temperature threshold.
The L1000-A is automatically shut down when the temperature exceeds the
shutdown upper limit.

Verifying and diagnosing transceiver modules

Verifying transceiver modules

To verify transceiver modules, you can use the display transceiver interface command to display the key

parameters of the transceiver modules, including transceiver module type, connector type, central

wavelength of the laser sent, transfer distance, and vendor name.
To display the transceiver module information:

Task Command

Remarks

Display key parameters of the
transceiver module in a

specified interface.

display transceiver interface

[ interface-type interface-number ]

Available for all transceiver
modules.

Diagnosing transceiver modules

The L1000-A provides the alarm function for transceiver modules for diagnosis.
To display the alarm information about transceiver modules:

Advertising