MLC 52 Series MediaLink Controllers • Installation

Wiring for IR control

If you intend to control display and/or input devices via infrared (IR) commands
from the MLC, you can connect Extron IR emitters or an IR Broadcaster to the
IR Out pin of the control connector. Up to two IR emitters can be connected via this
connector at one time. Wire the connector as shown in the following illustrations.

MLC 52
control
connector

For the IR Emitter only

IR

Emitter

White striped wire only

+12VDC output

For the IR Broadcaster with emitter port

For a wired projector remote port

IR

MLC 52
control
connector

IR

MLC 52
control
connector

IR

Demodulated IR

Ground

Demodulated IR

Ground

Modulated IR

Ground

100 feet (30.5 m) maximum

Connect up
to 2 IR
Emitters
(max.)
(#70-283-01).

Place the head of each IR Emitter
over or directly adjacent to the
controlled device’s IR receiver.

To the projector's
wired remote port

(Connector type and
pin configurations may
vary depending on the
projector model.)

To IR Broadcaster
with Emitter port
(#60-272-02)

D

E

A

D

E

D

E

F E D C B A

F E D C B A

F E D C B A

Wiring the control connector for IR