Extron electronic MEDIALINK MLC 52 User Manual

Page 57

Advertising
background image

4-13

MLC 52 Series MediaLink Controllers • Special Applications

Projector remote control type B (application 3)

This remote control has only two input buttons — one for the RGB inputs and one
for the S-video and composite video inputs. Each of these buttons contains two
commands (commands “A” and “B”) that cause the button to toggle between
inputs.

Following these steps, use IR learning to program the input selection commands
from the projector’s type B hand-held remote control onto the MLC’s PC and Video
or blank (VC models) buttons.

Programming RGB inputs — projector remote control type B

1.

Place the rear panel configuration DIP switch #1 in the On (up)
position to enter learning mode.

2

.

Using IR learning, program command “A” from the RGB input selection
button on the projector’s remote control into memory block #1 of the
MLC 52’s PC button as follows:

a

.

Press the PC button on the MLC front panel. The button blinks,
indicating that the MLC is ready to learn the command. On the rear
panel, the bottom IR learning LED flashes.

b

.

Within 5 seconds (while the PC button on the MLC 52 is blinking), press
the RGB button on the projector’s remote control. The MLC has learned
command “A” for RGB.

When a command has been successfully learned, the IR learning LEDs on the
MLC rear panel flash in rapid progression from the top to the bottom, then
back to the top.

3

.

Program the input selection command “B” from the RGB input selection
button on the projector’s remote control into memory block #2 of the
MLC 52’s PC button as follows:

a

.

Press the PC button on the MLC front panel. The button blinks,
indicating that the MLC is ready to learn the command. On the rear
panel, the second LED from the bottom flashes.

b

.

Within 5 seconds (while the PC button on the MLC 52 is blinking), press
the RGB button on the projector’s remote control. The MLC has learned
command “B” for RGB.

4

.

If finished programming the MLC 52 buttons, return configuration DIP
switch #1 to its Off (down) position, and test the system.

If you want to program video input selection at this time, proceed to
“Programming video inputs — type B remote control,” on the next page.

1

ON

2 3 4

Advertising