Description and Specifications 1-7

Model 3081FG

1-3 SPECIFICATIONS

Net O

2

Range....................................................................... 0 to 25% O

2

Fully Field Selectable via the HART Interface

Lowest Limit................................................................. 0.05% O

2

Highest Limit................................................................ 25.00% O

2

Accuracy .............................................................................. ±1.5% of reading or 0.05% O

2

, whichever is greater

System Response to Calibration Check Gas ...................... Initial response in less than 3 seconds

T90 in less than 10 seconds

PROBE
Lengths ................................................................................ 20 in. (508 mm)

26 in. (660 mm)
34.625 in. (880 mm)

Temperature Limits

Process Temperature Limits........................................ 550° to 1400°C (1022° to 2552°F)

Operation to 1600°C (2912°F) with reduced cell life.

Ambient........................................................................ -40° to 149°C (-40° to 300°F) Ambient

Mounting and Mounting Position ......................................... Vertical or Horizontal
Materials of Construction

Process Wetted Parts
Inner Probe .................................................................. Zirconia
Outer Protection Tube ................................................. Alumina [1600°C (2912°F) limit]

Inconel 600 [1000°C (1832°F) limit]

Probe Junction Box ..................................................... Cast aluminum

Speed of Installation/Withdrawal ......................................... 1 in. (25.4 mm) per minute
Hazardous Area Certification............................................... Intrinsically safe per EN50 014 (1977), clause 1.3(1)
Reference Air Requirement ................................................. 100 ml per minute (0.2 scfh) of clean, dry instrument

air; 1/4 in. tube fittings

Calibration Check Gas Fittings ............................................ 1/4 in. tube fittings
Cabling................................................................................. Two twisted pairs, shielded

(1)

Thermocouple and O

2

probe cell are both unpowered, developing a millivolt emf, and are considered a

“simple apparatus” by certifying agencies.