Figure 2-2), Ange (figure 2-3), Model 3081fg – Emerson 3081FG User Manual

Page 21: Instruction manual

Advertising
background image

Instruction Manual

IB-106-3081 Rev. 1.5

September 2002

Rosemount Analytical Inc. A Division of Emerson Process Management

Installation 2-3

Model 3081FG

29750002

PLATE DIMENSIONS

DIMENSION

ANSI

4512C34G01

DIN

4512C36G01

JIS

4512C35G01

“C” DIA.

4.75 (121)

5.71 (145)

5.12 (130)

“B” THREAD

0.625-11

M-16x2

M-12x1.75

“A”

6.00 (153)

7.5 (191)

6.50 (165)

METAL WALL

STACK OR DUCT

MASONRY WALL

STACK

3.00 SCHEDULE 40

PIPE SLEEVE

SUPPLIED BY CUSTOMER

WELD OR BOLT ADAPTER

PLATE TO STACK OR DUCT.

JOINT MUST BE AIR TIGHT.

WELD PIPE TO

ADAPTER PLATE

JOINT MUST

BE AIR TIGHT

B

C

A

A

NOTE: DIMENSIONS ARE

IN INCHES WITH
MILLIMETERS IN
PARENTHESES.

3.50 (89)

O.D. REF

2.50 (63.5)
MIN. DIA.

Figure 2-2. Optional Adapter Plate

TAP 1.25 NPT

0.50 (12.7)

C

B

A

FLANGE DIMENSIONS

DIMENSION

ANSI

5R10158H01

DIN

5R10158H02

JIS

5R10158H03

MODEL 450

5R10158H04

“C” DIA.

4.75 (121)

5.71 (145)

5.12 (130)

7.68 (195)

“B” DIA.

0.75 (20)

0.71 (18)

0.59 (15)

0.50 (13)

“A” DIA.

6.00 (153)

7.28 (185)

6.10 (155)

9.00 (229)

29750003

NOTE: DIMENSIONS ARE IN

INCHES WITH MILLIMETERS
IN PARENTHESES.

Figure 2-3. Optional Probe Mounting Flange