Pd6210 process input – Precision Digital PD6310 User Manual

Page 11

Advertising
background image

Model PD6210 & PD6310 Batch Controllers

Instruction Manual

11

ENCLOSURE

1/8 DIN, high impact plastic, UL 94V-0, color: black

MOUNTING

1/8 DIN panel cutout required:
3.622" x 1.772" (92 mm x 45 mm)
Two panel mounting bracket assemblies are provided.

TIGHTENING
TORQUE

Screw terminal connectors: 5 lb-in (0.56 Nm)

OVERALL
DIMENSIONS

4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm)
(W x H x D)

WEIGHT

9.5 oz (269 g)

WARRANTY

3 years parts & labor

PD6210 Process Input

INPUTS

Field selectable:
0-20, 4-20 mA,

±10 V (0-5, 1-5, 0-10 V), Modbus PV (Slave)

ACCURACY

±0.03% of calibrated span ±1 count,
square root & programmable exponent accuracy range:
10-100% of calibrated span

TEMPERATURE
DRIFT

0.005% of calibrated span/

°C max from 0 to 65°C ambient,

0.01% of calibrated span/

°C max from -40 to 0°C ambient

SIGNAL INPUT
CONDITIONING

Linear, square root, or programmable exponent

MULTI-POINT
LINEARIZATION

2 to 32 points

PROGRAMMABL
E EXPONENT

1.0001 to 2.9999

LOW-FLOW
CUTOFF

0-999999 (0 disables cutoff function)

DECIMAL POINT

Up to five decimal places or none:

d.ddddd

, d.dddd, d.ddd, d.dd, d.d,

or

dddddd

CALIBRATION
RANGE

Input
Range

Minimum Span
Input 1 & Input 2

4-20 mA 0.15 mA
±10 V

0.10 V

An error message will appear if the input 1 and input 2
signals are too close together.

INPUT
IMPEDANCE

Voltage ranges: greater than 500 k

Ω

Current ranges: 50 - 100

Ω

(depending on resettable fuse impedance)

INPUT
OVERLOAD

Current input protected by resettable fuse, 30 VDC max.
Fuse resets automatically after fault is removed.

F4 DIGITAL INPUT
CONTACTS

3.3 VDC on contact. Connect normally open contacts
across F4 to COM.

Advertising
This manual is related to the following products: