Setting up the interlock relay (force on) feature – Precision Digital PD6310 User Manual

Page 61

Advertising
background image

Model PD6210 & PD6310 Batch Controllers

Instruction Manual

61

Setting Up the Interlock Relay (Force On) Feature

Relays 1-4 can be set up as interlock relays. To set up the relays for the
interlock feature:
1. Access the SetupRelayAction menu and set the action to off.


2. In the Advanced features – User menu program any of the digital

inputs to Force On any of the internal relays (1-4).

3. Connect a switch or dry contact between the +5V terminal and the

corresponding digital input (dI-1 to dI-4) terminal.

1

2

3

4

5

6

+5

I1

I2

I3

I4

O1

7

8

O2

O3

9

10

O4

G

DI 1-4

DO 1-4

5 VDC

GND

SW2

SW1

Interlock Relay Operation Example

Relays 3 & 4 are configured to energize (their front panel LEDs are off)
when SW1 & SW2 switches (above) are closed. If the contacts to these
digital inputs are opened, the corresponding front panel LEDs flash
indicating this condition. The processes being controlled by the interlock

Advertising