Model PD6210 & PD6310 Batch Controllers

Instruction Manual

91

Troubleshooting Tips

Symptom Check/Action

No display at all

Check power at power connector

Not able to change setup or
programming, Locd is displayed

Controller is password-protected, enter
correct six-digit password to unlock

Controller displays error message
during calibration (Error)

Check:
1. Signal

connections

2. Input

selected

in

Setup

menu

3.

Minimum input span requirements

Controller displays

999999

-99999

Check:
1. Input

selected

in

Setup

menu

2.

Corresponding signal at Signal
connector

Display is unstable

Check:
1.

Input signal stability and value

2.

Display scaling vs. input signal

3.

Filter and bypass values (increase)

Display response is too slow

Check filter and bypass values

Display reading is not accurate

1.

Signal input conditioning selected:
Linear, square root, etc.

2.

Scaling or calibration

Display does not respond to input
changes, reading a fixed number

Check:

Display assignment, it might be
displaying max, min, or set point.

Display alternates between

1.

Hi

and a number

2.

Lo

and a number

Press Menu to exit max/min display
readings.

Relay operation is reversed

Check:
1.

Fail-safe in Setup menu

2.

Wiring of relay contacts

Relay and status LED do not
respond to signal

Check:
1. Relay

action

in

Setup

menu

2.

Set and reset points

Flashing relay status LEDs

Relays in manual control mode or relay
interlock switches opened.

Controller not communicating with
application programs

Check:
1.

Serial adapter and cable

2. Serial

settings

3.

Controller address and baud rate

If the display locks up or the
controller does not respond at all

Cycle the power to reboot the
microprocessor.

Other symptoms not described
above

Call Technical Support for
assistance.

Note: Certain sequences of events can cause unexpected results. To solve these
issues, it is best to start fresh from factory defaults and map changes ahead of
time, rather than at random.