Model PD6210 & PD6310 Batch Controllers

Instruction Manual

28

Modbus RTU Serial Communications

Serial communications connection is made to an RJ45 connector labeled
M-LINK on Figure 7. Use the PDA1232 for RS-232 interfacing, the
PDA1485 for RS-485 interfacing, or the PDA8008 for USB interfacing. The
same port is used for interfacing with all expansion modules (e.g. external
relays, digital I/O).
Use the PDA1200 controller copy cable for meter-to-meter interfacing for
cloning purposes (i.e. copying settings from one controller to other
controllers).

Relay Connections

Relay connections are made to two six-terminal connectors labeled
RELAY1 – RELAY4 on Figure 7. Each relay’s C terminal is common
only to the normally open (NO) and normally closed (NC) contacts of the
corresponding relay. The relays’ C terminals should not be confused with
the COM (common) terminal of the INPUT SIGNAL connector.

C

NO

NO

NC

NC

C

RELAY4

RELAY3

4

3

6

5

2

1

C

NO

NO

NC

NC

C

RELAY2

RELAY1

4

3

6

5

2

1

Figure 18: Relay Connections