Model PD6210 & PD6310 Batch Controllers

Instruction Manual

24

Power Connections

Power connections are made to a two-terminal connector labeled POWER
on Figure 6. The controller will operate regardless of DC polarity
connection. The + and - symbols are only a suggested wiring convention.

AC or DC

POWER

Required External Fuse:

5 A max, 250 V Slow Blow

POWER

+ -

Figure 8: Power Connections

PD6210 Signal Connections

Signal connections are made to a six-terminal connector labeled
SIGNAL on Figure 6. The COM (common) terminal is the return for the
4-20 mA and the

±10 V input signals.

Current and Voltage Connections

The following figures show examples of current and voltage connections.
There are no switches or jumpers to set up for current and voltage inputs.
Setup and programming is performed through the front panel buttons.

Figure 9: Transmitters Powered by Internal Supply