Modbus rtu serial communications, Relay connections, Relay4 relay3 – Precision Digital PD6400 User Manual

Page 23: Relay2 relay1

Advertising
background image

Model PD6400 High Voltage & Current Meter

Instruction Manual

23

Modbus RTU Serial Communications

Serial communications connection is made to an RJ45 connector
labeled M-LINK on Figure 6. For interfacing to the P

RO

V

U

®

, use the

PDA1232 for RS-232, the PDA1485 for RS-485, or the PDA8008 for
USB. The same port is used for interfacing with all expansion modules
(e.g. external relays, digital I/O).

Use the PDA1200 meter copy cable for meter-to-meter interfacing for
cloning purposes (i.e. copying settings from one meter to other meters).

Relay Connections

Relay connections are made to two six-terminal connectors labeled
RELAY1 – RELAY4 on Figure 6. Each relay’s C terminal is common
only to the normally open (NO) and normally closed (NC) contacts of the
corresponding relay. The relays’ C terminals should not be confused
with the COM (common) terminal of the INPUT SIGNAL connector.

Figure 16. Relay Connections

C

NO

NO

NC

NC

C

RELAY4

RELAY3

4

3

6

5

2

1

C

NO

NO

NC

NC

C

RELAY2

RELAY1

4

3

6

5

2

1