Remote Processing RPC-210 User Manual

Page 18

Advertising
background image

SAVING CODE AND DATA

BASIC

SECTION 3

Page 3-5

RPBASIC-52 Programm ing manual differences

The limits for the commands listed below are different
than shown in the RPBA SIC-52 m anual.

Command

RPBAS IC-52

manual

RPC-210

PEEK B

segment = 0 to 7

segment = 0 to 15

PEEK F

segment = 0 to 7

segment = 0 to 15

PEEK W

segment = 0 to 7

segment = 0 to 15

PEEK $

segment = 0 to 7

segment = 0 to 15

The ma in difference is PE EK type com mands access
segments from 0 to 15 instead of 0 to 7. segments 8-15
are from F lash EPROM . D ata is saved to Flash using
BSAVE. See LOA D_SAV .BAS for access exam ples.

POKE type commands only write to RAM.

NOTE: Futur e version (Per haps starting in 2012) will

have an enhanded BSAVE com mand. The
newer BSA VE com mand will have an erase
flash sector capability. Contact R emote
Processing for mor e information.

APPLICATION PROGRAMS

The following program s are in the BASIC52 directory.

F i le N a me

Description

ARRAYS.BAS

Program fragment to store and
read mixed data types from
R A M .

LOAD_SAV.BAS

Uses BLOAD /BSAVE for
Flash access, PEEK/ POKE
commands for data access. See
NOT E about future versions of
BSAVE com mand.

EXEC1.BAS thru
EXEC7.BAS

7 programs show how one
program calls another
randomly.

EXECCLR.BAS

Clears counters used by
EXEC x.BAS.

HEXLOAD.BAS

Receives Intel HEX file and
stores data into segme nt 1
R A M .

VERIFYRP.BAS

Verifies that RPBASIC-52 sent
to RAM segment 1 = Flash
E P R OM .

Advertising