RAM

BASIC

SECTION 5

Page 5-3

RPBASIC-52 Programm ing manual differences

The limits for the commands listed below are different
than shown in the RPBA SIC-52 m anual.

Command

RPBA SIC

manual

RPC-210

PEEK B

segment = 0 to 7

segment = 0 to 15

PEEK F

segment = 0 to 7

segment = 0 to 15

PEEK W

segment = 0 to 7

segment = 0 to 15

PEEK $

segment = 0 to 7

segment = 0 to 15

The ma in difference is PE EK type com mands access
segments from 0 to 15 instead of 0 to 7. segments 8-15
are from F lash EPROM . D ata is saved to Flash using
BSAVE. See LOA D_SAV .BAS for access exam ples.
See Note above regarding changes to BSAVE command
starting about 2012..

POKE type commands only write to RAM.

APPLICATION PROGRAMS

The following program s are in the BASIC52 directory.

F i le N a me

Description

ARRAYS.BAS

Program fragment to store and
read mixed data types from
R A M .

LOAD_SAV.BAS

Uses BLOAD /BSAVE for
Flash access, PEEK/ POKE
commands for data access. See
note about changes to BSAVE
command starting about 2012.