Remote Processing RPC-210 User Manual

Page 48

Advertising
background image

ANALOG I/O

BASIC

SECTION 10

Page 10-6

Gener ally, y ou have a fe w milli-am ps for you r circ uit.
You may be able to get more than this in your
circumstance.

Unfortuna tely, the only w ay to tell is to try it. The best
way to tell is to connect the devices to the board and load
the ± supplies. M easure the voltages. J10-18 should be
a t l ea st 7. 5 V , i f y o u w i ll us e t he 0 -5 V A / D a n d D / A
range. J10-20 should be about -5V.

An alternative is to put analog I/O in the 2.5V max.
range. Then use the + 5V supply for amplifier supply.

APPLICATION PROGRAMS

Program s are in the BASIC52 directory.

P r og r am N a m e

Description

AIN-1.BAS

All channe ls printed ou t,
including tem peratur e. P rints
out actual voltage at pin.

AIN-2.BAS

P e r fo r m s t im e d A / D
conversions using ON TICK.

AIN-3.BAS

Figures offse t and gain error s.
Stores and retrieves calibration
constants.

210CAL.BAS

Prom pts you to adjust R16 and
calibrate e ach chann el.
Requires an external reference
of 4.900 volts.

J10 ANALOG I/O CONNECTOR PIN OUT

The table below is a pin out for analog connector J10.

J1 Pin

N a m e

1

Analog inp ut 0

2

Ground

3

Analog inp ut 1

4

Ground

5

Analog inp ut 2

6

Ground

7

Analog inp ut 3

8

Ground

9

Analog inp ut 4

10

Ground

11

Analog inp ut 5

12

Ground

13

Analog inp ut 6

14

Ground

15

Analog inp ut 7

16

Ground

17

Analog ou tput 0

18

About + 8V

19

Analog ou tput 1

20

About -8V

Advertising