Rs-232, Menu list – Roland P-20HD Video Instant Replayer User Manual

Page 63

Advertising
background image

63

Menu List

14: RS-232

Menu item

Value

(Bold: default)

Explanation

Baudrate

9600

, 38400bps

Specifies the communication speed (bps) of the RS-232 connector.

Remote Control

This sets how the remote control is used.

Off

Disables remote control.

PC

Remotely controls the P-20HD from a controlling device such as your computer.

Switcher

Synchronizes playback of the clip or playlist on the P-20HD with the video transition on

your Roland video switcher.

Target Model (*5)

V-60HD

Sets the video switcher used to synchronize with the P-20HD.

Input Channel (*5)

Ch5,

Ch6

Select the channel of the video switcher to which the P-20HD video is input.

Host/Remote (*5)

Host

, Remote

Sets whether the P-20HD acts as the host (operating other devices) or the remote (being

operated by other devices).

Time Offset at Play

Start (*6) (*7)

0–

40–

200ms

Adjusts how long it takes before the video transition starts on the other video switcher

after the clip or playlist starts playing back on the P-20HD.

Time Offset at Play

End (*6) (*7)

-200–

-40–

0ms

Adjust the time it takes before the video transition starts, so that the video transition

finishes on the other video switcher when the clip or playlist stops playing back on the

P-20HD.

(*6) This can be set if Remote Control is “Switcher.”
(*7) This can be set if Host/Remote is “Host.”

15: LAN

Menu item

Value

(Bold: default)

Explanation

IP Setting

Selects how settings are made for the IP address, subnet mask, and default gateway.

Off

Disables the network connection.

Using DHCP

The IP address and other information needed for connecting to the network is obtained

automatically from the DHCP server of the LAN.

Manually

This is to be configured manually.

IP Address (*8)

---.---.---.---

Specifies the IP address as appropriate for the network to which the unit is connected.

Subnet Mask (*8)

---.---.---.---

Specifies the subnet mask as appropriate for the network to which the unit is connected.

Gateway (*8)

---.---.---.---

Specifies the default gateway as appropriate for the network to which the unit is

connected.

MAC Address

00:00:00:00:00:00

(example display)

Displays the MAC address.

User Account

This configures the necessary user account to connect to the network.

User ID

Sets the user ID (4–8 characters).

Password

Sets the password (8–12 characters).
* When you set a different password, there is no need to input the old password or

perform a reset operation.

* If a password has been set, “************” is displayed.

Reset

[Exec]

Resets the user ID and password.

Remote Control

Off

, On

When this is set to “On,” the unit receives remote control commands from the network

device.

FTP

Off

, On

When this is set to “On”, you can access the “/P-20HD_Export” folder that’s located on the

SD card or USB storage device connected to the P-20HD, via FTP from your computer.
You can work with the following files from your FTP client.

¹

Downloading/uploading an exported project archive

¹

Downloading an exported video, EDL or FCPXML file

Directory (*9)

SD Card

, USB Memory

Sets the media (SD card or USB storage) to access from your computer when connecting

via FTP. The contents of the “/P-20HD_Export” folder on the respective storage media are

shared.

Status

Offline, Online

Displays the FTP connection status.

(*8) This can be set if IP setting is “Manually.”
(*9) This can be set if FTP is “Off.”