Alarm Module Terminal Definition

There are 36 terminals on the alarm module. The positions and indexes are described

in Fig 2.7. The definitions are described in Table 2.5.

Fig. 2.7 Alarm Module Terminal Definition

The definitions of the alarm module terminals are defined in the following table:

Table 2.5 The Definition of LEDs on the Alarm Module

No

Terminal

name

Function

No Terminal

name

Function

1 Alarm1_In

Alarm signal input 1

19 Alarm5_In

Alarm signal input 5

2

GND GND

20

GND GND

3 Alarm2_In

Alarm signal input 2

21 Alarm6_In

Alarm signal input 6

4 Alarm3_In

Alarm signal input 3

22 Alarm7_In

Alarm signal input 7

5

GND GND

23

GND GND

6 Alarm4_In

Alarm signal input 4

24 Alarm8_In

Alarm signal input 8

7 Alarm1_NO

Alarm 1 output for normally-open 25 Alarm5_NO

Alarm 5 output for normally-open

8 Alarm1_COM Alarm 1 output in common

26 Alarm5_COM Alarm 5 output in common

9 Alarm1_NC

Alarm 1 output for normally-close 27 Alarm5_NC

Alarm 5 output for normally-close

10 Alarm2_ NO Alarm 2 output for normally-open 28 Alarm6_ NO Alarm 6 output for normally-open
11 Alarm2_ COM Alarm 2 output in common

29 Alarm6_ COM Alarm 6 output in common

12 Alarm2_ NC

Alarm 2 output for normally-close 30 Alarm6_ NC

Alarm 6 output for normally-close

13 Alarm3_ NO Alarm 3 output for normally-open 31 Alarm7_ NO Alarm 7 output for normally-open
14 Alarm3_ COM Alarm 3 output in common

32 Alarm7_ COM Alarm 7 output in common

15 Alarm3_ NC

Alarm 3 output for normally-close 33 Alarm7_ NC

Alarm 7 output for normally-close

16 Alarm4_ NO Alarm 4 output for normally-open 34 Alarm8_ NO Alarm 8 output for normally-open
17 Alarm4_ COM Alarm 4 output in common

35 Alarm8_ COM Alarm 8 output in common

18 Alarm4_ NC

Alarm 4 output for normally-close 36 Alarm8_ NC

Alarm 8 output for normally-close