Enter alarm action setting sub-menu – EverFocus EFC--02-1-A User Manual

Page 57

Advertising
background image

49

Alarm Action Setting menu is used to configure alarm outputs of all events on main

module and door module. The submenu for arm zone events will not appear if no

alarm module is installed.

Extended Alarm Setting menu is used to configure alarm outputs of all events on

alarm module. This menu will not appear if no alarm module is installed.

Alarm Time Setting is used to configure the time period of alarm outputs.

Enter Alarm Action Setting Sub-menu

The following window appears after entering the Alarm Setting menu:

Press

ENT

to enter Alarm Action Setting menu. The first submenu is for fire alarm

outputs. Use

and

to choose from different alarm menus for different

events. Alarm output configuration for all events is basically the same. As an example,

alarm output configuration for invalid card event is introduced below. The figure

below shows the menu interface:

The upper line indicates the card to be configured, i.e., invalid card. The first 8

characters of the lower line are alarm output status of this event on the door module,

while the 2 characters following the minus sign are alarm output status on the Main

alarm output and Auxiliary alarm output on the main module. Y indicates there is

alarm output (relay energized) and N indicates there is no alarm output (relay not

energized). R refers specifically to alarm output relay on the door module, indicating

that alarm output will be generated only if the event occurs on the corresponding

door.

In the above example, the alarm output relay on door #1 will be energized if and only

if the access request on door #1 is denied due to the invalid card event. On the

contrary, the alarm output relay on door #8 will be energized as long as an invalid

card event occurs. For alarm output relay on door #2~7, no alarm output will be

generated due to the invalid card event. The NN following the minus sign indicates

no alarm output from the Main alarm output and Auxiliary alarm output on main

module when an invalid card event occurs.

In this menu, press numeric key 1~8 to toggle the alarm output status of this event

on the door module among Y, N, and R. Press numeric key 9,0 to toggle the alarm

output status of this event on the Main alarm output and Auxiliary alarm output on

the main module between Y and N.

Alarm Action
Setting

Invalid Card
RNNNNNNY-NN