Connecting Power

Connecting the Power Supply

Connect the positive end to the terminal 18 on the main module and the GND to

terminal 19 on the main module, as shown in Fig. 4.1.

V

V

Fig. 4.1 Connection to Power Supply

The voltage supply for EverAccess controller can handle a range of DC 9V ~18V.

The maximum current draw of the controller is 500 mA. If the backup battery is

connected to the controller, a power supply with DC15V output is required. The

power supply in the EverAccess enclosure is DC15V. In addition, the controller

provides a 12V power supply for the card readers. It should be noted that if a

controller powers multiple card readers, the current draw will be increased. The total

current draw can be calculated as below:

controller

to

connected

readers

reader

controller

number

current

Current

×

+

= 500

Important Tips: The voltage supply should be located no more than 2

meters from the controller. Also, electric locks and alarm devices MUST be

powered separately. The controller’s power supply can power the controller

and modules, and the card readers, but NOT the locking hardware or alarm

devices.