Connection to a Magnetic Lock

Fig. 2.11 Example for Connecting a Magnetic Lock

Terminals 11 ~13 are for Door 1 and terminals 27~29 are for Door 2 connections.

Please NOTE:

1.

The maximum current outputted by the door lock relay on the door
module is less than 5A. If the current for door lock exceeds the capacity,
an external power relay is needed.

2.

V+ in the figures represents one lead of power from an external power

source. When using DC Voltage for the lock, put the positive lead here.
When using AC the leads are interchangeable.


Connection to Door Sensor

The interface to the door sensor is also provided by the door module: door sensor 1

corresponds to terminal 9-10 and corresponds to 25-26 on the door module.

Fig. 2.12 Example for Connecting Door Sensor to Controller

Terminals 9 ~10 are for Door 1 and terminals 25~26 are for Door 2 connections.