Connection to Door Lock

Electric strikes and magnetic locks are used to keep doors locked unless the system

grants access or the user sets the doors to remain unlocked. The installer must supply

the electric strikes and/or magnetic locks. It is recommended that the installer follow

and keep the instructions for these locks. One strike or mag lock is required for each

door. These locks must be powered separately from the readers. The mounting

instructions for strikes and mag locks vary depending on the manufacturer and type

of lock. Please consult the instructions included with the door hardware when

installing. Once the locks are installed, follow the instructions below to connect them

to the controller.

Each door module provides an interface to two door control relays. Terminals 11

~13 are for door 1 connections and terminals 27~29 are for door 2 connections.

Terminals 12 and 28 are named common terminals (COM). Terminals 13 and 29 are

used for normally closed terminal (N.C.) locks. Terminals 11 and 27 are used for

normally open terminal (N.O.) locks.

The electrical door lock must have a separate power supply. The power supply for the

electrical door lock depends on the specification of the lock. Carefully choose the

cable connecting the door locks to fit the current draw. Two common types of

electrical door locks in the market are electric strike locks and magnetic locks. The

connection methods for these examples are shown in Fig. 2.10 and 2.11 respectively.


Connection to an Electric Strike

Fig.2.10 Example for Connecting an Electric Strike

Terminals 11 ~13 are for Door 1 and terminals 27~29 are for Door 2 connections.

COM

N.O

.

V-

V+

(29)

(28)

(27)

12

11

13

Door

module