Armzone setting, Reader lost, Enter alarm time setting sub-menu – EverFocus EFC--02-1-A User Manual

Page 63: Enter armzone setting menu

Advertising
background image

55

Reader Lost

A Reader Lost event will be generated when controller detects that the card reader

has no signal. The default setting for Alarm Action Setting and Extended Alarm

Setting is: corresponding relay on door module has alarm output, Main alarm output

on main module has alarm output, and no alarm output is generated on alarm module

per reader lost event, as shown in the following two figures, respectively. Change

settings according to sections “Enter Alarm Action Setting Sub-menu” and “Enter

Extended Alarm Setting Sub-menu”.

Enter Alarm Time Setting Sub-menu

According to system setting, if alarm is triggered by certain event, alarm output will

remain active until user resets the alarm or certain period of time called alarm time

has elapsed. In Alarm Time setting user can set the alarm time, i.e., the time an alarm

output remains active.

Under Alarm menu, press

twice to bring up the following window:

Press

ENT

to enter Alarm Time Setting submenu. The current alarm time will be

displayed as shown below. Use numeric keys to enter the desired alarm time. Enter

minutes as a 3-digit number 0~999 and seconds as a 2-digit number 0~59. The
default value of alarm time is 1 minute. Press

ENT

to confirm. Press

to exit

without effecting any change.

Armzone Setting

After an alarm module is installed, it defines 8 arm zones for its 8 alarm inputs.

EverAccess Flex Controller can treat alarm inputs in 8 arm zones in a very flexible

manner. These 8 arm zones can be armed or disarmed on the controller. For how to

arm/disarm the system, please refer to later section “ARM/DISARM”.

Enter Armzone Setting Menu

Under System menu, press

five times to bring up the following window:

Reader Lost
NNNNNNNN

Reader Lost
RRRRRRRR-YN

Alarm Time
Setting

Alarm Time
001M00S

ArmZone Setting