EXCEL 10 FCU CONTROLLER LNS PLUG-INS USER GUIDE

EN2B-0285GE51

R0909

21

Terminal Block Assignment and Wiring Example for the W7752 Controller

Table 11 illustrates terminal block assignments and wiring for

an example Excel 10 W7752 FCU Controller installation.

Table 12 lists wiring information for all possible actuator types.

Table 11. W7752 Controller: Overview of terminals and functions (by model)

model

terminal

#

function

D

E

F

G

J

1

GND serving terminals 2 and 3

3

3

3

3

3

2

a digital input, configurable (using the LNS plug-in) to read input e.g. from a

window contact, an occupancy sensor, etc.

3

3

3

3

3

3

a digital output, permanently configured to write output switching the wall module's

LED ON/OFF

3

3

3

3

3

4

an analog input, permanently configured to read input from a wall module's

temperature setpoint adjustment knob

3

3

3

3

3

5

an analog input, permanently configured to read input on whether the wall

module's 3-speed fan control knob has been set to AUTO, OFF, LOW, MEDIUM,

or HIGH and whether the wall module's "occupancy override" button has been

pressed

3

3

3

3

3

6

an analog input, permanently configured to read input from a room temperature

sensor

3

3

3

3

3

7

GND serving terminals 4, 5, and 6

3

3

3

3

3

8 not

used

-- -- -- -- --

9+10

receiving/sending data on the L

ON

W

ORKS

network

3

3

3

3

3

11+12

sending/receiving data on the L

ON

W

ORKS

network

3

3

3

3

3

13

a common terminal for terminals 14 and 15

3

3

3

3

3

14

a triac output, permanently configured to write output to OUT1, opening it

3

3

3

3

3

15

a triac output, permanently configured to write output to OUT1, opening it

3

3

3

3

3

16

a common terminal for terminals 17 and 18

3

3

3

3

3

17

a triac output, permanently configured to write output to OUT2, opening it

3

3

3

3

3

18

a triac output, permanently configured to write output to OUT2, closing it

3

3

3

3

3

19

a common terminal for terminals 20, 21, and 22

3

3

3

3

3

20

(1)

relay 1, permanently configured to write output to a three-speed fan, setting it to

LOW

3

3

3

3

3

21

(1)

relay 2, permanently configured to write output to a three-speed fan, setting it to

MEDIUM

3

3

3

3

3

22

(1)

relay 3, permanently configured to write output to a three-speed fan, setting it to

HIGH

3

3

3

3

3

23

the "L" terminal of the power supply (230 Vac, 115 Vac, or 100 Vac, respectively)

230 230 115

115

100

24

the "N" terminal of the power supply (230 Vac, 115 Vac, or 100 Vac, respectively)

230 230 115

115

100

25+26

relay 4, permanently configured to write output to a hardwired electrical reheat

coil, switching it ON/OFF

3

-- 3 -- --

(1)

If all three relays (terminals 20, 21, and 22) are switched OFF, the three-speed fan will likewise be switched OFF.

Using Honeywell's LNS plug-in, you can configure the controller's triac outputs and relay outputs for a variety of different

functions. E.g. the triac outputs can be configured for connection to either a floating drive or to a thermal actuator. Once the

outputs have been configured, the corresponding devices can be directly connected to them.

Table 12. Output assignments of Excel 10 W7752 FCU Controller for various actuator types

out 1 terminal

out 2 terminal

output type

13

14

15

16

17

18

floating

24 Vac

open

close

24 Vac

open

close

1-stage

24 Vac

ON/OFF

24 Vac

ON/OFF

2-stage

24 Vac

stage 1

stage 2

24 Vac

stage 1

stage 2

24 Vac

stage 1

stage 2

24 Vac

stage 1

stage 2

3-stage

stage 3

stage 3

PWM

24 Vac

PWM

24 Vac

PWM

thermal

24 Vac

ON/OFF

24 Vac

ON/OFF