Operating overview 2-29 – HP 2500C Series User Manual

Page 87

Advertising
background image

Operating Overview 2-29

421

MECH_BAD_BLACK_PEN

Not used – pen/ flexcable/ Carriage PCA/ Logic PCA error

Black pen had bad ID or TSR.

422

MECH_BAD_CYAN_PEN

Not used – pen/ flexcable/ Carriage PCA/ Logic PCA error

Cyan pen had bad ID or TSR.

423

MECH_BAD_MAGENTA_PEN

Not used – pen/ flexcable/ Carriage PCA/ Logic PCA error

Magenta pen had bad ID TSR.

424

MECH_BAD_YELLOW_PEN

Not used – pen/ flexcable/ Carriage PCA/ Logic PCA error

Yellow pen had bad ID TSR.

425

MECH_BLACK_OOI

Not used – ISS/ Harness/ Logic PCA error

Black out of ink trap.

426

MECH_CYAN_OOI

Not used – ISS/ Harness/ Logic PCA error

Cyan out of ink trap.

427

MECH_MAGENTA_OOI

Not used – ISS/ Harness/ Logic PCA error

Magenta out of ink trap.

428

MECH_YELLOW_OOI

Not used – ISS/ Harness/ Logic PCA error

Yellow out of ink trap.

429

MECH_UDV_PROB

Not used

12V supply was out of spec (was 424).

431

MECH_PEN_E_5_SHORT

Pen failed

Electrical short test on 5 V failed.

432

MECH_SS_FAILURE

Service Station/ harness / Logic PCA error

SS jammed or SS OPTO failure.

433

MECH_NO_RAMP_MEMORY

Not used

Downloadable ramp allocation memory failed.

434

MECH_BAD_SPIT_FREQ

Not used - Logic PCA/ bad pen

Spit Frequency or Spit Count out of range.

435

MECH_PEN_VP1_SHORT

Pen / Logic PCA/ carriage base/ Flexcable connection error

Electrical short test on VP1 failed.

436

MECH_PEN_VP2_SHORT

Pen / Logic PCA/ carriage base/ Flexcable connection error

Electrical short test on VP2 failed.

437

MECH_PEN_E_12_SHORT

Pen / Logic PCA/ carriage base/ Flexcable connection error

Electrical short test on 12 V failed.

438

MECH_ALL_PENS_BAD

Not used – pen issue/ Logic PCA/ Carriage base

All 4 pens have a bad ID. This error could be caused
By a short on one of the pens, which cannot be
specifically identified.

439

MECH_CARRIAGE_LATCH_ERROR

Not used – Recoverable error

The carriage latch is open.
This error should become something more
benign.

441

MECH_PUMP_JAM

ISS pump motor jam – ISS/ Logic PCA / Harness

Pump could not move to desired position.

442

MECH_STALLED_MOTOR_ENCODER

Encoder wheel / Linefeed PCA / Logic PCA error

Motor stall: paper encoder signal.

443

MECH_STALLED_MOTOR_EMF

Not used

Motor stall: EMF signal.

444

MECH_PAPER_ENCODER

Encoder wheel / linefeed PCA / Logic PCA error

Thrown when quadrature calibration fails.

445

MECH_NUDGE_ERROR

Not used

Nudge position error outside limits.

446

MECH_PAPER_JAM_ERROR

Not able to feed out media / Linefeed motor / Linefeed PCA error

Paper jam while ejecting.

451

MECH_PEN_SHORT_OVER

Pen issue / Logic PCA / carriage base error

Pen Short Test failed (voltage increase).

452

MECH_DARWIN_OVERTEMP

Darwin Senior Failed – PCA

Darwin over temperature.

453

MECH_DARWIN_JR_OVERTEMP

Darwin Junior Failed – PCA

Darwin Jr over temperature.

454

MECH_RESISTOR_TEST_FAIL

Not used - pen issue/ flex cable/ carriage base/ logic PCA

Resistor test > 100 nozzle failure.

455

MECH_SS_OUTOFLIMITS

Service Station / Logic PCA

SS could not be homed within reasonable limit.

456

MECH_SS_DIRTYPON1

Service Station / Logic PCA

SS could not be freed from carriage - case 1.

457

MECH_SS_DIRTYPON2

Service Station / Logic PCA

SS could not be freed from carriage - case 2.

458

MECH_SS_DIRTYPON3

Service Station / Logic PCA

SS could not be freed from carriage - case 3.

459

MECH_SS_DIRTYPON4

Service Station / Logic PCA

SS could not be freed from carriage - case 4.

461

MECH_SHORT_TIMER

Pen short detected – pen issue

The short test was not completed within required time.

462

MECH_SS_REHOMING_ERROR

Service Station/ Logic PCA

Error while rehoming service station.

463

MECH_SPIT_POSITION_ERROR

Firmware error – Encoder strip / SS / carriage base/ Logic PCA

Error in spit position.

464

MECH PAPERMOTOR NO INDEX

Not used

Thrown when index mark is not found.

Advertising