Honeywell MK VI User Manual

Page 184

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

184

TABLE 5.3.2-11: AIR DATA INPUT SELECT #11

SIGNAL

CONNECTION

REFERENCE

SUMMARY DATA

Uncorrected Barometric
Altitude

(+) = J1-62
(–) = J1-43

6.1.16

Format: DC with Validity Flag
Input Type: Basic
Fault Designation: BAROMETRIC ALTITUDE FAULT
Validity: Barometric Alt Valid (+28V)

Outside Air Temp
Total Air Temperature

Probe element
Excitation:

Temp Input
(probe element):

Ground

5 V = J1-25

(+) = J1-63
(–) = J1-44

GND = J1-53

6.1.4
4.2.3.5

4.2.10

Format: DC
Input Type: Basic
Fault Designation: STATIC AIR TEMPERATURE FAULT

OAT PROBE

ELEMENT

25

J1

(5 V Ref)

63
44

Temp In

4.42 K Ohms

53

Voat

Chassis Gnd

-

+

Note: Nominal 500

Temperature Probe only.

Resistance @ 0

°

C: 500

±

0.6

Connection example:
CIC Temperature Sensor, P/N 05257 (2 wire). Connect positive
lead to both J1-25 and J1-63. Connect negative lead to both J1-44
and J1-53 (Chassis Ground).

Other probes may have three contacts.

Computed Airspeed

No Connection

N/A

Substitute Ground Speed for Airspeed (airspeed is not available with this air data
input)

PIN FUNCTION

CONNECTION

PIN TYPE

CHANNEL

DESIGNATION

REFERENCE

Polarity/Configuration

References

Barometric Altitude
Validity Discrete (+28V)

J1-9

Input

28V_DISC_08

>+17V = Valid

< +4.4V = Invalid

6.6.22

4.2.7

Configuration Data

Type

Summary Data

Derive Baro Altitude Rate

Analog

Baro Altitude Rate is derived using
Uncorrected Barometric Altitude.
Although the ADC’s provide Baro Rate,
the EGPWS does not have an analog
connection available.

Advertising