Honeywell MK VI User Manual

Page 186

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

186

TABLE 5.3.2-255: AIR DATA INPUT SELECT #255

CHANNEL
429/422RX_1

CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data
Uncorrected Baro. Alt
Corrected Baro. Alt
Computed Airspeed
True Airspeed
Barometric Rate
Static Air Temperature

Reference
6.2.1
6.2.38
6.2.39
6.2.40
6.2.3
6.2.2

Label
203
204
206
210
212
213

Sig. Bits
17
17
14
15
11
11

Range
±131,072 FT
±131,072 FT
±1024 KTS
±2048 KTS
±32678 FPM
±512 Degrees

Signal Type
Basic
Basic
Basic
Basic
Basic
Basic

Resolution
1.0
1.0
0.0625
0.0625
16.0
0.25

Rate (ms)
31.3-62.5
31.3-62.5
62.5-125
62.5-125
31.3-62.5
250-500

CHANNEL
429RX_3

CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data
Uncorrected Baro. Alt
Corrected Baro. Alt
Computed Airspeed
True Airspeed
Barometric Rate
Static Air Temperature

Reference
6.2.1
6.2.38
6.2.39
6.2.40
6.2.3
6.2.2

Label
203
204
206
210
212
213

Sig. Bits
17
17
14
15
11
11

Range
±131,072 FT
±131,072 FT
±1024 KTS
±2048 KTS
±32678 FPM
±512 Degrees

Signal Type
Basic
Basic
Basic
Basic
Basic
Basic

Resolution
1.0
1.0
0.0625
0.0625
16.0
0.25

Rate (ms)
31.3-62.5
31.3-62.5
62.5-125
62.5-125
31.3-62.5
250-500

Advertising