Table 5.3.6.1-251

Honeywell Primus EPIC CDS/R, with binary Peaks Elevations

MK VIII Only

Display Configuration Group 251

Function

Value

Reference section

Display Type

Honeywell Integrated Primus Epic CDS/R (Control Display
System/Retrofit), with binary peaks elevations

Sweep Type

Honeywell

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Auto Pop Up

Category 7 does not affect pop up logic. The display controls pop up,
therefore enable/disable of pop up is done via the display.

5.3.7

Category 7, Options Select Group #1

Peaks Enable: False

Peaks Enable: True

Peaks Mode

Peaks Off

Peaks On

5.3.7

Binary Peaks Elevations

Yes - Data passed by ARINC 429, Labels 011 and 012

Manual select

Selection is controlled by display

Manual deselect

Deselection is controlled by display

Auto Range

Yes 10NM

Moving Marker

No

Overlay Page

No

Display Priority

Standard

Display bus type

Honeywell picture bus

DISPLAY BUS #1 & #2
453TX_1

CONNECT TO:

A = J1-58
B = J1-59

Honeywell left/right interleaved picture bus to MFD and PFD

4.2.13.2
7.2

CONNECT TO:
Not supported for this display type

Display Input Control Group 250

CHANNEL
429_422RX_1

CONNECT TO: IOC #1 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data
FWC & GP discrete word

Reference
6.2.48

Label
171

Sig. Bits
Format 1
Bits 15-18
Bits 25-28

Range
Type 1
2000NM
Discrete

Signal Type
Basic

Resolution
N/A

Rate (ms)
100

CHANNEL
429RX_3

CONNECT TO: IOC #2 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data
FWC & GP discrete word

Reference
6.2.48

Label
171

Sig. Bits
Format 1
Bits 15-18
Bits 25-28

Range
Type 1
2000NM
Discrete

Signal Type
Basic

Resolution
N/A

Rate (ms)
100

Output 429 Bus Group 0

Channel

Pins

Comments

429TX_1 (Low Speed)

A = J2-43
B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, 7.1.4.x, 7.1.5.x, and 7.1.6.x

429TX_2 (Low Speed)

A = J2-26
B = J2-9

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, 7.1.4.x, 7.1.5.x, and 7.1.6.x

Integration Notes:
1. The EGPWS ARINC 429 Output Bus must be connected to the display.
2. Display channels 1 and 2 are multiplexed on ARINC 453 Bus 1.
3. This configuration will cause the GPWS INOP, TERRAIN INOP, and WINDSHEAR INOP lamps to turn on only at

the beginning of the EGPWS Self Test.

4. This display uses the following ARINC 429 labels from the EGPWS for annunciation’s:

Label 011/012

Upper/Lower Peaks Elevations – “xxx/xxx” on PFD and MFD.

Label 050

If bits 11-14 left range output from EGPWS does not match left MFD range (via label 171), then display
white “RANGE MISMATCH” on left PFD and MFD.