Honeywell MK VI User Manual

Page 218

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

218

Table 5.3.6.1-235

Collins ProLine 4 (Non-Integrated)

Display Configuration Group 2

Function

Value

Reference section

Display Type

Collins ProLine 4

Sweep Type

Standard with +/-60 degree limit

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Auto Pop Up

Pop Up On Caution or Warning

Never Pop Up

5.3.7

Category 7, Options Select Group #1

Peaks Enabled: False

Peaks Enabled: True

Peaks Mode

Peaks Off

Peaks On

5.3.7

Manual select

Anytime

Manual deselect

Anytime

Auto Range

No

Moving Marker

No

Overlay Page

Yes, “TERR” or Peaks Elevations located on upper left side of Terrain
image.

Display bus type

ARINC 453

DISPLAY BUS #1
453TX_1

CONNECT TO:

A = J1-58
B = J1-59

Terrain Display data to switching relay/Symbol Generator

4.2.13.2
7.2

DISPLAY BUS #2
453TX_2

CONNECT TO:

A = J1-56
B = J1-57

Terrain Display data to switching relay/Symbol Generator

4.2.13.2
7.2

Display Input Control Group 244

CHANNEL
429_422RX_1

CONNECT TO: IOC #1 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data
Range (Mode/Range Word)

Reference
6.2.21

Label
155

Sig. Bits
Discrete

Range
5-640NM

Signal Type
Basic

Resolution
N/A

Rate (ms)
50

CHANNEL
429RX_3

CONNECT TO: IOC #2 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41

1

B = J2-40

Data
Range (Mode/Range Word)

Reference
6.2.21

Label
155

Sig. Bits
Discrete

Range
5-640NM

Signal Type
Basic

Resolution
N/A

Rate (ms)
50

CONN PIN #

REFERENCE NAME

PIN FUNCTION

Polarity/Configuration

J1-32

GND_DISC_12

Reference
4.2.7
6.6.18

Display Select Discrete #1

Type 1 (Momentary)
Gnd = Display Select Toggle
<not> Gnd = Normal

J1-31

GND_DISC_13

Reference
4.2.7
6.6.19

Display Select Discrete #2

Type 1 (Momentary)
Gnd = Display Select Toggle
<not> Gnd = Normal

Output 429 Bus Group 0

Channel

Pins

Comments

429TX_1 (Low Speed)

A = J2-43
B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, and 7.1.4.x

Integration Notes:
1. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input

channels. This prevents the EGPWS from reporting an external bus fault on the second channel.