Honeywell MK VI User Manual

Page 227

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

227

Table 5.3.6.1-245

Honeywell SPZ8000, EDZ806, (Integrated) with dual SCI range

MK VIII Only

Display Configuration Group 250

Function

Value

Reference section

Display Type

Honeywell (SPZ8000 new style) every fourth display line is blanked

Sweep Type

Honeywell

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Auto Pop Up

Pop Up On Caution or Warning

Never Pop Up

5.3.7

Category 7, Options Select Group #1

Peaks Enable: False

Peaks Enable: True

Peaks Mode

Peaks Off

Peaks On

5.3.7

Manual select

Selection is controlled by display

Manual deselect

Deselection is controlled by display

Auto Range

Yes 10NM

Moving Marker

Yes (Honeywell type)

Overlay Page

Yes for Peaks Elevations only (located middle right of display)

Display bus type

Honeywell picture bus

DISPLAY BUS #1
453TX_1

CONNECT TO:

A = J1-58
B = J1-59

Terrain Display data to switching relay/Symbol Generator #1 and MFD left channel

4.2.13.2
7.2

DISPLAY BUS #2
453TX_2

CONNECT TO:

A = J1-56
B = J1-57

Terrain Display data to switching relay/Symbol Generator #1 and MFD right channel

4.2.13.2
7.2

Display Input Control Group 249

CHANNEL
429_422RX_1

CONNECT TO: SCI Bus 1
Format: RS-422 (12.0K baud)

Fault Designation: DISPLAY BUS 1
Bus Type: Basic

A = J2-36
B = J2-37

Data
Range (Mode/Range word)
Status

Reference
6.5.1.1
6.5.1.2

Label
80
FF

Sig. Bits
4 discrete
Discrete

Range
2000NM
N/A

Signal Type
Basic
Basic

Resolution
N/A
N/A

Rate (ms)
100
100

CHANNEL
429RX_3

CONNECT TO: SCI Bus 2
Format: RS-422 (12.0K baud)

Fault Designation: DISPLAY BUS 2
Bus Type: Basic

A = J2-10
B = J2-11

Data
Range (Mode/Range word)
Status

Reference
6.5.1.1
6.5.1.2

Label
80
FF

Sig. Bits
4 discrete
Discrete

Range
2000NM
N/A

Signal Type
Basic
Basic

Resolution
N/A
N/A

Rate (ms)
100
100

Output 429 Bus Group 0

Channel

Pins

Comments

429TX_1 (Low Speed)

A = J2-43
B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, and 7.1.4.x

Integration Notes:
1.

The EGPWS ARINC 429 Output Bus must be connected to the display.

2.

The ‘DISPLAY BUS’ fault will be present only if both MG inputs have failed.

3.

The Honeywell EFIS SG & MG provide Terrain display relay control.

4.

When interfacing to a single display controller configuration the bus must be connected to both EGPWS input

channels. This prevents the EGPWS from reporting an external bus fault on the second channel.

5.

The display uses the following ARINC 429 labels from the EGPWS for annunciations. The Terrain display will

annunciate: “TERR” in green or cyan (depending on the program) when the Terrain is selected and valid.
“TERR” in amber if Terrain is selected and any of the following conditions are TRUE:

The EGPWS ARINC 429 output bus is missing or labels 050 and 051 are absent or unreadable for 2 seconds.

EGPWS ARINC label 051 bit 13 = 0 (“Terrain Display Valid” bit FALSE).

EGPWS ARINC label 050 bit 17 = 1 (“Terrain Inhibit” bit TRUE).

EGPWS ARINC labels are valid, but the range in label 050 disagrees with the range via SCI bus label 80 (label

050 bit 11-14 contain left display bus range and bits 15-18 are the right display bus range).

The display will be blanked when the amber “TERR” is present.
The display will Pop Up to Terrain mode as follows:

Advertising
This manual is related to the following products: