Table 5.3.11-3: Heading Input Select Type 3

CHANNEL

429RX_7

CONNECT TO: AHRS
Format: ARINC 429 (High Speed)

Fault Designation: AHRS BUS
Bus Type: Basic

A = J2-23

B = J2-6

Data

Magnetic Heading

True Heading

Reference

6.2.32
6.2.37

Label

320
314

Sig. Bits

15
15

Range

±180 degrees
±180 degrees

Signal Type

Basic
Basic

Resolution

0.0054931640625
0.0054931640625

Rate (ms)

10-20
25-50

Table 5.3.11-254: Heading Input Select 254

CHANNEL

429/422RX_1

CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data

True Heading

Reference

6.2.32

Label

314

Sig. Bits

15

Range

±180 degrees

Signal Type

Basic

Resolution

0.0054931640625

Rate (ms)

25-50

CHANNEL

429RX_3

CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data

True Heading

Reference

6.2.32

Label

314

Sig. Bits

15

Range

±180 degrees

Signal Type

Basic

Resolution

0.0054931640625

Rate (ms)

25-50

Table 5.3.11-255: Heading Input Select 255

CHANNEL

429/422RX_1

CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data

Magnetic Heading

Reference

6.2.32

Label

320

Sig. Bits

15

Range

±180 degrees

Signal Type

Basic

Resolution

0.0054931640625

Rate (ms)

25-50

CHANNEL

429RX_3

CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data

Magnetic Heading

Reference

6.2.32

Label

320

Sig. Bits

15

Range

±180 degrees

Signal Type

Basic

Resolution

0.0054931640625

Rate (ms)

25-50