Honeywell MK VI User Manual

Page 58

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

58

62

43

9

25

63

44

53

J1

Altitude Out

Signal Common

BIT Out

Analog Air Data Computer

EGPWS MK VI / MK VIII

(+)

(-)

Uncorrected

Barometric

Altitude

Baro Altitude Valid +28V

(+)

(-)

Temp. Input

Chassis Ground

+5V Excitation

500 ohm

Temperature

Probe

Analog-ADC.vsd

Cat 2

Uncorrected Baro Altitude

1

Vendor Model

ID

Altitude Out

Common

BIT Out

CIC 04077

0

J1-F

J1-G

J1-E

Collins ADS-65

3

J1-12

J1-13

J1-5

CIC 02702

4

J1-A

J1-B

J1-E

Honeywell AZ-241

11/12

2

J1A-63

J1A-11

(CGND)

J1A-12

Honeywell AZ-242

4

11/12

2

J1B-17

4

J1A-11

(CGND)

J1A-12

Honeywell AZ-648

11/12

2

J1-J

J1-G

J1-U

Honeywell AZ-800

3

11/12

2

J1A-78

J1A-10

(CGND)

J1A-34

Honeywell AZ-810

3

11/12

2

J1A-78

J1A-10

(CGND)

J1A-34

Honeywell AZ-252

11/12

2

J1A-17

J1A-10

(CGND)

J1A-34

NOTES:

1

The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS engineering. Please
contact the manufacturer’s customer service to confirm your installation.

2

ID 12 does not require an OAT input, instead a constant temperature of 25 deg C is assumed.

3

Honeywell AZ-810 should only be used as an analog source if it does not have a digital interface.

4

Honeywell AZ-242 with part numbers 4013242-708, -709, -710, -712, -713 and –742 have DC Altitude out at pin J1B-17. Part
numbers 4013242-709 and -711 have DC Altitude out at pin J1A-40.

Advertising
This manual is related to the following products: