Table 5.3.8-254: Radio Altitude Input Select Type 254 (ARINC 429 via dual IOC buses)

CHANNEL

429RX_1

CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data

Radio Altitude

Decision Height (format 3)

MDA (format 3)

Reference

6.2.29
6.2.41
6.2.51

Label

164
370
170

Sig. Bits

16
16
16

Range

±8192 FT
±8192 FT

±65536 FT

Signal Type

Basic
Basic
Basic

Resolution

0.125
0.125

1.0

Rate (ms)

25-50

100-200

200

CHANNEL

429RX_3

CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data

Radio Altitude

Decision Height (format 3)

MDA (format 3)

Reference

6.2.29
6.2.41
6.2.51

Label

164
370
170

Sig. Bits

16
16
16

Range

±8192 FT
±8192 FT

±65536 FT

Signal Type

Basic
Basic
Basic

Resolution

0.125
0.125

1.0

Rate (ms)

25-50

100-200

200

Table 5.3.8-255: Radio Altitude Input Select Type 255 (ARINC 429 via dual IOC buses)

CHANNEL

429RX_1

CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data

Radio Altitude

Decision Height (format 1)

Reference

6.2.29
6.2.41

Label

164
370

Sig. Bits

16
16

Range

±8192 FT
±8192 FT

Signal Type

Basic
Basic

Resolution

0.125
0.125

Rate (ms)

25-50

100-200

CHANNEL

429RX_3

CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data

Radio Altitude

Decision Height (format 1)

Reference

6.2.29
6.2.41

Label

164
370

Sig. Bits

16
16

Range

±8192 FT
±8192 FT

Signal Type

Basic
Basic

Resolution

0.125
0.125

Rate (ms)

25-50

100-200