Honeywell MK VI User Manual

Page 208

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

208

Table 5.3.6.1-9

Honeywell/Bendix EFIS 40/50 (Non-Integrated)

Display Configuration Group 7

Function

Value

Reference section

Display Type

Bendix EFIS 40/50 (Non-Integrated)

Sweep Type

Sweep range +/- 60 degrees

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Auto Pop Up

Pop Up when display is in the
proper mode.

Never Pop Up

5.3.7

Category 7, Options Select Group #1

Peaks Enabled: False

Peaks Enabled: True

Peaks Mode
(Elevations via overlay)

Peaks Off

Peaks On

5.3.7

Manual select

Anytime WXR is on and display is in proper Mode

Manual deselect

Anytime

Auto Range

No

Moving Marker

No

Overlay Page

Yes, “TERR” at middle right of the display. Peaks Elevations located
middle right of display.

Display bus type

ARINC 453

DISPLAY BUS #1
453TX_1

CONNECT TO:

A = J1-58
B = J1-59

Terrain Display data to switching relay/Symbol Generator

4.2.13.2
7.2

DISPLAY BUS #2
453TX_2

CONNECT TO:

A = J1-56
B = J1-57

Terrain Display data to switching relay/Symbol Generator

4.2.13.2
7.2

Display Input Control Group 2

CHANNEL
429_422RX_1

CONNECT TO: WX-IND Bus 1 out
Format: ARINC 429 (Low Speed)

Fault Designation: DISPLAY BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data
Mode (Display Word 1)
Range (Display Word 2)
Discrete Word (Vertical Profile)

Reference
6.2.26
6.2.20
6.2.27

Label
270
271
273

Sig. Bits
Discrete
Discrete
Discrete

Range
Mode, Tilt, Gain
5-320NM
VP Mode, Bit 11

Signal Type
Basic
Basic
Basic

Resolution
N/A
N/A
N/A

Rate
100 ms
100 ms
100 ms

CHANNEL
429RX_3

CONNECT TO: WX-IND Bus 2 out
Format: ARINC 429 (Low Speed)

Fault Designation: DISPLAY BUS 2
Bus Type: Basic

A = J2-41

1

B = J2-40

Data
Mode (Display Word 1)
Range (Display Word 2)
Discrete Word (Vertical Profile)

Reference
6.2.26
6.2.20
6.2.27

Label
270
271
273

Sig. Bits
Discrete
Discrete
Discrete

Range
Mode, Tilt, Gain
5-320NM
VP Mode, Bit 11

Signal Type
Basic
Basic
Basic

Resolution
N/A
N/A
N/A

Rate
100 ms
100 ms
100 ms

CONN PIN #

REFERENCE NAME

PIN FUNCTION

Polarity/Configuration

J1-32

GND_DISC_12

Reference
4.2.7
6.6.18

Display Select Discrete #1

Type 1 (Momentary)
Gnd = Display Select Toggle
<not> Gnd = Normal

J1-31

GND_DISC_13

Reference
4.2.7
6.6.19

Display Select Discrete #2

Type 1 (Momentary)
Gnd = Display Select Toggle
<not> Gnd = Normal

Output 429 Bus Group 0

Channel

Pins

Comments

429TX_1 (Low Speed)

A = J2-43
B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, and 7.1.4.x

Integration Notes:

1. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input

channels. This prevents the EGPWS from reporting an external bus fault on the second channel.