Honeywell MK VI User Manual

Page 200

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

200

Table 5.3.6.1-0

KC Picture Bus

Display Configuration Group 0

Function

Value

Reference section

Display Type

KC Picture Bus (KCPB)

2

Sweep Type

Curtain (Vertical or Horizontal scan)

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Auto Pop Up

Pop Up On Caution or Warning

Never Pop Up

5.3.7

Category 7, Options Select Group #1

Peaks Enable: False

Peaks Enable: True

Peaks Mode
(Elevations via overlay)

Peaks Off

Peaks On

5.3.7

Manual select

None (Display controls selection)

Manual deselect

None (Display controls selection)

Auto Range

Controlled by display response (if selected a 10 NM range will be used)

Moving Marker

None

Overlay Page

Controlled by display

Display bus type

KCPB

DISPLAY BUS #1
453TX_1

CONNECT TO:

A = J1-58
B = J1-59

Terrain Display data

4.2.13.2
7.2

DISPLAY BUS #2
453TX_2

CONNECT TO:

A = J1-56
B = J1-57

Terrain Display data

4.2.13.2
7.2

Display Input Control Group 0

CHANNEL
429_422RX_1

CONNECT TO: KCPB-IND Bus 1 out
Format: ARINC 429 (Low Speed)

Fault Designation: KCPB BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data
Range

3

Query/Continuous Response
DSU Status Data (DSU only)
Key Press/Display Mode

3

Reference
6.2.35
6.2.24
6.2.36
6.2.25

Label
271
011
350
012

Sig. Bits
11
Discrete
Discrete
Discrete

Range
0.5-1023.5NM
N/A
N/A
N/A

Signal Type
Basic
Basic
Basic
Basic

Resolution
0.5
N/A
N/A
N/A

Rate (ms)
250
1000
1000
250

CHANNEL
429RX_3

CONNECT TO: KCPB-IND Bus 2 out
Format: ARINC 429 (Low Speed)

Fault Designation: KCPB BUS 2
Bus Type: Basic

A = J2-41

1

B = J2-40

Data
Range

3

Query/Continuous Response
DSU Status Data (DSU only)
Key Press/Display Mode

3

Reference
6.2.35
6.2.24
6.2.36
6.2.25

Label
271
011
350
012

Sig. Bits
11
Discrete
Discrete
Discrete

Range
0.5-1023.5NM
N/A
N/A
N/A

Signal Type
Basic
Basic
Basic
Basic

Resolution
0.5
N/A
N/A
N/A

Rate (ms)
250
1000
1000
250

Output 429 Bus Group 0

Channel

Pins

Comments

429TX_1 (Low Speed)

A = J2-43
B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x , and 7.1.4.x

Integration Notes:

1.

When interfacing to a single display controller configuration the Display Input bus must be connected to both
EGPWS input channels. This prevents the EGPWS from reporting an external bus fault on the second channel.

2.

KCPB (Keyed Component Picture Bus) is also known as ASPB (AlliedSignal Picture Bus)

3.

Label 012 is optional. The current fault and fault history message “RANGE” for label 271 (Range) is not shown if
Range Keys are requested on label 012 (Key Press/Display Mode).

4.

The Display group is configured by the Display using response labels on its ARINC 429 data bus.

5.

KCPB bus types use “Inop & Warning Annunciations in same Window” therefore during EGPWS Self Test the
Fail lights will not remain on throughout the test.