Honeywell MK VI User Manual

Page 231

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

231

Table 5.3.6.1-248

Honeywell Primus 1000

MK VIII Only

Display Configuration Group 248

Function

Value

Reference section

Display Type

Honeywell Primus 1000

Sweep Type

Honeywell

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Auto Pop Up

Pop Up On Caution or Warning

Never Pop Up

5.3.7

Category 7, Options Select Group #1

Peaks Enable: False

Peaks Enable: True

Peaks Mode

Peaks Off

Peaks On

5.3.7

Manual select

Selection is controlled by display

Manual deselect

Deselection is controlled by display

Auto Range

Yes 10NM

Moving Marker

Yes (Honeywell type)

Overlay Page

Yes, for Peaks Elevations only (located middle right side of the display)

Display bus type

Honeywell picture bus

DISPLAY BUS #1 & #2
453TX_1

CONNECT TO:

A = J1-58
B = J1-59

Terrain Display data to switching relay/Symbol Generator

4.2.13.2
7.2

CONNECT TO:
Not supported for this display type

Display Input Control Group 248

CHANNEL
429_422RX_1

CONNECT TO: IC600 #1 FDR Bus
Format: ARINC 429 (High Speed)

Fault Designation: FDR BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data
Range
Discrete Word

Reference
6.2.23
6.2.28

Label
050
275

Sig. Bits
Bits 11-14
Bit 17

Range
2000NM
Discrete

Signal Type
Basic
Basic

Resolution
N/A
N/A

Rate (ms)
100
500

CHANNEL
429RX_3

CONNECT TO: IC600 #2 FDR Bus
Format: ARINC 429 (High Speed)

Fault Designation: FDR BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data
Range
Discrete Word

Reference
6.2.23
6.2.28

Label
050
275

Sig. Bits
Bits 11-14
Bit 17

Range
2000NM
Discrete

Signal Type
Basic
Basic

Resolution
N/A
N/A

Rate (ms)
100
500

Output 429 Bus Group 0

Channel

Pins

Comments

429TX_1 (Low Speed)

A = J2-43
B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, and 7.1.4.x

Integration Notes:
1. The EGPWS ARINC 429 Output Bus must be connected to the display.

2.

Display channels 1 and 2 are multiplexed on ARINC 453 bus 1.

3.

The system only has one range for terrain display on MFD, therefore the range to use depends on the value of label
275, bit 17.

8. The Terrain display will Pop-Up in response to EGPWS label 274, bit 28 (Left display) and bit 29 (right display).
9. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input

channels. This prevents the EGPWS from reporting an external bus fault on the second channel.

10. This configuration will cause the GPWS INOP, TERRAIN INOP, and WINDSHEAR INOP lamps to turn on only at

the beginning of the EGPWS Self Test.

Advertising
This manual is related to the following products: