Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

232

Table 5.3.6.1-249

Honeywell Primus EPIC CDS/R, (Integrated) with overlay

Peaks Elevations

MK VIII Only

Display Configuration Group 249

Function

Value

Reference section

Display Type

Honeywell Primus EPIC CDS/R (Control Display System/Retrofit) with
overlay Peaks elevation

Sweep Type

Honeywell

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Auto Pop Up

Category 7 does not affect pop up logic. The display controls pop up,
therefore enable/disable of pop up is done via the display.

5.3.7

Category 7, Options Select Group #1

Peaks Enable: False

Peaks Enable: True

Peaks Mode

Peaks Off

Peaks On

5.3.7

Manual select

Selection is controlled by display

Manual deselect

Deselection is controlled by display

Auto Range

Yes 10NM

Moving Marker

No

Overlay Page

Yes, for Peaks Elevations only (located on lower right side of display)

Display Priority

Standard

Display bus type

Honeywell picture bus

DISPLAY BUS #1 & #2
453TX_1

CONNECT TO:

A = J1-58
B = J1-59

Honeywell left/right interleaved picture bus to MFD and PFD

4.2.13.2
7.2

CONNECT TO:
Not supported for this display type

Display Input Control Group 250

CHANNEL
429_422RX_1

CONNECT TO: IOC #1 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data
FWC & GP discrete word

Reference
6.2.48

Label
171

Sig. Bits
Format 1
Bits 15-18
Bits 25-28

Range
Type 1
2000NM
Discrete

Signal Type
Basic

Resolution
N/A

Rate (ms)
100

CHANNEL
429RX_3

CONNECT TO: IOC #2 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data
FWC & GP discrete word

Reference
6.2.48

Label
171

Sig. Bits
Format 1
Bits 15-18
Bits 25-28

Range
Type 1
2000NM
Discrete

Signal Type
Basic

Resolution
N/A

Rate (ms)
100

Output 429 Bus Group 0

Channel

Pins

Comments

429TX_1 (Low Speed)

A = J2-43
B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, and 7.1.4.x

Integration Notes:
1. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input

channels. This prevents the EGPWS from reporting an external bus fault on the second channel.

2. The ‘IOC BUS’ fault will be present only if both MG inputs have failed.
3. The Honeywell EFIS SG & MG provide Terrain display relay control.
4. The EGPWS ARINC 429 Output Bus must be connected to the display
5. This configuration will cause the GPWS INOP, TERRAIN INOP, and WINDSHEAR INOP lamps to turn on only at

the beginning of the EGPWS Self Test.

6. Display channels 1 and 2 are multiplexed on ARINC 453 bus 1.
7. This display uses the following ARINC 429 labels from the EGPWS for annunciations:

Label 050

If bits 11-14 left range output from the EGPWS does not match left MFD range (via label 171), then
display white “RANGE MISMATCH” on the left PFD and MFD.