Honeywell MK VI User Manual

Page 223

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

223

Table 5.3.6.1-240

Collins Pro Line 21 (Integrated) with overlay Peaks Elevations

MK VIII Only

Display Configuration Group 245

Function

Value

Reference section

Display Type

Collins ProLine 21 Integrated, with overlay peaks elevations and partial
compass raster patch

Sweep Type

Fan Mode with +/- 90 degree limit

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Auto Pop Up

Category 7 does not affect pop up logic. The display controls pop up,
therefore enable/disable of pop up is done via the display.

5.3.7

Category 7, Options Select Group #1

Peaks Enable: False

Peaks Enable: True

Peaks Mode

Peaks Off

Peaks On

5.3.7

Manual Select

Selection is controlled by display

Manual Deselect

Deselection is controlled by display

Auto Range

Yes (10 NM) controlled by display

Moving Marker

No

Overlay Page

Yes, for Peaks Elevations only (located upper right side of display)

Display bus type

ARINC Compatible Format – Collins ProLine 21 (label 077)

Terrain Mode
Annunciation

ProLine 21 system outputs Terrain Mode annunciation, it does not use
EGPWS ASCII message.

DISPLAY BUS #1
453TX_1

CONNECT TO:

A = J1-58
B = J1-59

Terrain Display data to Primary Flight Display/Multi Function display #1

4.2.13.2
7.2

DISPLAY BUS #2
453TX_2

CONNECT TO:

A = J1-56
B = J1-57

Terrain Display data to Primary Flight Display/Multi Function display #2

4.2.13.2
7.2

Display Input Control Group 254

CHANNEL
429RX_1

CONNECT TO: IOC #1 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data
Range (Mode/Range Word)

Reference
6.2.21

Label
176

Sig. Bits
Discrete

Range
5-640NM

Signal Type
Basic

Resolution
N/A

Rate (ms)
50

CHANNEL
429RX_3

CONNECT TO: IOC #2 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data
Range (Mode/Range Word)

Reference
6.2.21

Label
176

Sig. Bits
Discrete

Range
5-640NM

Signal Type
Basic

Resolution
N/A

Rate (ms)
50

Output 429 Bus Group 1

Channel

Pins

Comments

429TX_1 (Low Speed)

A = J2-43
B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, 7.1.4.x, and 7.1.6.x

429TX_2 (Low Speed)

A = J2-26
B = J2-9

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, 7.1.4.x, and 7.1.6.x

Integration Notes:
1. The EGPWS ARINC 429 Output Bus must be connected to the display.
2. The Terrain Display will Pop-Up in response to EGPWS label 274, bit 28 (left display) and bit 29 (right display).
3. This configuration will cause the GPWS INOP, TERRAIN INOP, and WINDSHEAR INOP lamps to turn on only at

the beginning of the EGPWS Self Test.

4. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input

channels. This prevents the EGPWS from reporting an external bus fault on the second channel.