Honeywell MK VI User Manual

Page 226

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

226

Table 5.3.6.1-244

Honeywell EDZ806 (non-Integrated) with dual SCI range

MK VIII Only

Display Configuration Group 239

Function

Value

Reference section

Display Type

Honeywell (Non-Integrated) EDZ806

Sweep Type

Honeywell

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Auto Pop Up

Pop Up On Caution or Warning

Never Pop Up

5.3.7

Category 7, Options Select Group #1

Peaks Enable: False

Peaks Enable: True

Peaks Mode
(Elevations via overlay)

Peaks Off

Peaks On

5.3.7

Manual select

Anytime except when display is in GMAP or Sector Scan mode

Manual deselect

Anytime

Auto Range

No

Moving Marker

Yes – a magenta underline will be alternately placed and removed under
the Peaks Elevations

Overlay Page

Yes for Peaks Elevations (located near the vertical center on the right edge
of the Terrain image)

Display bus type

Honeywell picture bus

DISPLAY BUS #1
453TX_1

CONNECT TO:

A = J1-58
B = J1-59

Terrain Display data to switching relay/Symbol Generator #1

4.2.13.2
7.2

DISPLAY BUS #2
453TX_2

CONNECT TO:

A = J1-56
B = J1-57

Terrain Display data to switching relay/Symbol Generator #2

4.2.13.2
7.2

Display Input Control Group 249

CHANNEL
429_422RX_1

CONNECT TO: SCI Bus 1
Format: RS-422 (12.0K baud)

Fault Designation: DISPLAY BUS 1
Bus Type: Basic

A = J2-36
B = J2-37

Data
Range (Mode/Range word)
Status

Reference
6.5.1.1
6.5.1.2

Label
80
FF

Sig. Bits
4 discrete
Discrete

Range
2000NM
N/A

Signal Type
Basic
Basic

Resolution
N/A
N/A

Rate (ms)
100
100

CHANNEL
429RX_3

CONNECT TO: SCI Bus 2
Format: RS-422 (12.0K baud)

Fault Designation: DISPLAY BUS 2
Bus Type: Basic

A = J2-10
B = J2-11

Data
Range (Mode/Range word)
Status

Reference
6.5.1.1
6.5.1.2

Label
80
FF

Sig. Bits
4 discrete
Discrete

Range
2000NM
N/A

Signal Type
Basic
Basic

Resolution
N/A
N/A

Rate (ms)
100
100

CONN PIN #

REFERENCE NAME

PIN FUNCTION

Polarity/Configuration

J1-32

GND_DISC_12

Reference
4.2.7
6.6.18

Display Select Discrete #1

Type 1 (Momentary)
Gnd = Display Select Toggle
<not> Gnd = Normal

J1-31

GND_DISC_13

Reference
4.2.7
6.6.19

Display Select Discrete #2

Type 1 (Momentary)
Gnd = Display Select Toggle
<not> Gnd = Normal

Output 429 Bus Group 0

Channel

Pins

Comments

429TX_1 (Low Speed)

A = J2-43
B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, and 7.1.4.x

Integration Notes:

1. The display does not use EGPWS ARINC 429 Output Bus.
2. The display color palette is not compatible with Terrain in the GMAP mode. Peaks Elevations are outside of the scan

area in Sector Scan mode. Terrain will not be allowed to display in these modes.

3. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input

channels. This prevents the EGPWS from reporting an external bus fault on the second channel.

Advertising
This manual is related to the following products: