4.4.2 EGPWC Fro nt Panel Test Connector

The RS-232 interface with the EGPWC is accomplished via a test connector provided on the EGPWC front
panel (J3). This provides access for a PC test monitor and portable data loading capabilities. The mating
connector for the EGPWC test plug (P3) is a male, 15 pin, double density D-subminiature type (or equivalent).

The connection between the PC serial port connector (with standard DB9) and the EGPWC RS-232 interface is
defined as follows:

RS-232 Receive

RS-232 Transmit

RS-232 Ground

EGPWS Front Connector (J3)

Pin 3

Pin 4

Pin 1

Standard (PC)* DB9 Connector

Pin 2

Pin 3

Pin 5

*NOTE: Some PC Comm Ports have Pins 2 & 3 reversed from what is described above.

Connector, AMP 205161-1
Socket Contact, AMP 205090-1, QTY 3
M39029/63-368

P

COM

Connector, AMP 204513-2*

Pin Contact, 204370-2, QTY 4*

M39029/58-360

Backshell, AMP 745854-5

Jackscrew, AMP 747784-3

Grommet Set, AMP 747746-1

P3

2
3
5

3
4
1

Length as required (5' to 50')

* Alternate part number 748364-1 connector and 748333-4 or -7 pin contact.