Interface description document, Introduction, Part number – Honeywell MK VI User Manual

Page 159: Purpose, System overview, Document overview, References

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

159

APPENDIX E - Interface Description Document

1 INTRODUCTION
1.1 Part

Number

This document is the Interface Description Document for the MK VI and MK VIII Enhanced Ground Proximity Warning
System (EGPWS). The EGPWS computer (EGPWC) for these systems are identified by Honeywell part numbers:
965-1180-0XX

MK VI EGPWC

With upgraded CPU

965-1190-0XX

MK VI EGPWC

With upgraded CPU and internal GPS

965-1210-0XX:

MK VIII EGPWC

With upgraded CPU

965-1220-0XX:

MK VIII EGPWC

With upgraded CPU and internal GPS

Differences, where they exist, between the different part numbers, are highlighted within this document.
The EGPWC 10 digit part number will identify the configuration of the EGPWC as follows:
965-1ABC-DDD (example 965-1180-020)
A = 1 (MK VI) or 2 (MK VIII)
B = Functionality of hardware (with or without internal GPS or Upgraded CPU). Refer to part number list above for
details.
C = MK VI or MK VIII EGPWC hardware (including boot code). C = 0 as hardware part numbers roll.
DDD = Application Software (including Configuration Software)
The Terrain Database (including the Envelope Modulation Database) Version is not identified in the 10-digit part number
but with a separate identifier on the nameplate.
All modification changes not affecting form, fit or function will be identified via “mod dots”.
The digits identifying the Application software will match the respective version number of the Application software.

1.2 Purpose

The Interface Description Document describes all of the system external interfaces for the MK VI and MK VIII Enhanced
Ground Proximity Warning System (EGPWS).

1.3 System

Overview

Refer to the EGPWS Product Specification document referenced in section 2.

1.4 Document

Overview

This document is organized as follows.
Section 1

Introduction, identifies this Description Document and describes the content and organization of the document.

Section 2

Referenced Documents.

Section 3

Mechanical Interface, summarizes the outline, mounting tray outline and weight of the EGPWS.

Section 4

Electrical Interface, summarizes the number and type of electrical interfaces available.

Section 5

Aircraft Application Data, specifies the available interfaces as well as specific data provided on each interface

Section 6

Input Data Definition, provides definition of digital and analog input characteristics.

Section 7

Output Data Definition, describes the characteristics of the EGPWC outputs.

Section 8

Connector Interface, describes pin out and function for the front panel connectors.

Section 9

Definitions, provides a list of acronyms.

2 REFERENCES

MK VI/MK VIII EGPWS Product Specification

965-1180-601

MK VI/MK VIII EGPWS Pilot Guide

060-4314-000

MK VI/MK VIII EGPWS Line Maintenance Manual

060-4199-180

MK VI/MK VIII EGPWS Terrain Database

060-4326-000

EGPWS Interface Methodology

060-4303-000

Advertising