4.2.4.2 Synchro Magnetic Heading

Quantity

1

Synchro Angle Range

±180 deg

Reference Voltages

±

26 VAC

RMS

± 20% (see 4.2.4.4)

Pin Assignment (Signal Mnemonic):

X leg
Y leg
Z leg

J1-22
J1-23
J1-3

(SYN_2X)
(SYN_2Y)
(SYN_2Z)

4.2.4.3 Synchro Pitch Attitude

Quantity

1

Synchro Angle Range

±80 deg

Reference Voltages

Not Required

Pin Assignment (Signal Mnemonic):

X leg
Y leg
Z leg

J1-5
J1-7
J1-6

(SYN_3X)
(SYN_3Y)
(SYN_3Z)

4.2.4.4 Configuration Defined Synchro Inputs

Quantity

2

Reference Voltages

±

26 VAC

RMS

± 20%

Pin Assignment (Signal Mnemonic):

#2 X leg
#2 Y leg
#2 Z leg

#3 X leg
#3 Y leg
#3 Z leg

J2-1
J2-2
J2-18

J2-19
J2-20
J2-3

(SYN_4X)
(SYN_4Y)
(SYN_4Z)

(SYN_5X)
(SYN_5Y)
(SYN_5Z)

4.2.4.5 Signal Timing Reference Inputs

These inputs accept 400 Hz AC signals, and detect the “zero crossings” of these signals. These zero crossings are used to
time the conversion and input of AC signals. Absolute voltage level of these signals is not measured, but it must be within
the range specified below. Voltage below the specified minimum value may result in intermittent or “jittery” zero cross
detection.

Timing reference signals are required for input of most AC devices (not required for pitch and roll). These references can be
brought into the appropriate timing reference input, or the system can be configured to derive a reference from the signal.
Timing reference signals are specified for synchro inputs requiring a range greater than

±

80 degrees. Inputs requiring less

(i.e., Roll Attitude) are configured to derive a reference from the synchro input signal and do not require a separate reference
voltage input.

Quantity

2

Input Impedance

> 140K

each line to signal ground

Maximum Reverse Fault Current

< 120

µ

A

A/C Input Signal Frequency Range

400 Hz,

±

10%

Maximum Input Voltage Swing (differential)

50V between input legs

Maximum Input Voltage Swing (ref. to Gnd)

50V from any leg to signal ground

Input Hardware Filtering

None

Minimum Input Voltage

±

0.5 VAC

Pin Assignment (Signal Mnemonic):

26VAC Reference #1 H
26VAC Reference #1 C

26VAC Reference #2 H
26VAC Reference #2 C

J1-4
J1-24

J2-34
J2-35

(26REF_1H)
(26REF_1L)

(26REF_2H)
(26REF_2L)