Fault designation: ioc bus 1, Arinc 429 via dual ioc buses with dh discrete) – Honeywell MK VI User Manual

Page 246

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

246

Table 5.3.8-251: Radio Altitude Input Select Type 251 (ARINC 429 via dual IOC buses with DH/MDA)

CHANNEL

429RX_1

CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data

Radio Altitude

Decision Height/MDA

Reference

6.2.29
6.2.62

Label

164
170

Sig. Bits

16

12 / 14

Range

±8192 FT

4096/16384

Signal Type

Basic
Basic

Resolution

0.125

1.0

Rate (ms)

25-50

1000

CHANNEL

429RX_3

CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data

Radio Altitude

Decision Height/MDA

Reference

6.2.29
6.2.62

Label

164
170

Sig. Bits

16

12 / 14

Range

±8192 FT

4096/16384

Signal Type

Basic
Basic

Resolution

0.125

1.0

Rate (ms)

25-50

1000

Table 5.3.8-252: Radio Altitude Input Select Type 252

(ARINC 429 via dual IOC buses with DH discrete)

CHANNEL

429RX_1

CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data

Radio Altitude

Decision Height (format 1)

Reference

6.2.29
6.2.41

Label

164
370

Sig. Bits

16
16

Range

±8192 FT
±8192 FT

Signal Type

Basic
Basic

Resolution

0.125
0.125

Rate (ms)

25-50

100-200

CHANNEL

429RX_3

CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data

Radio Altitude

Decision Height (format 1)

Reference

6.2.29
6.2.41

Label

164
370

Sig. Bits

16
16

Range

±8192 FT
±8192 FT

Signal Type

Basic
Basic

Resolution

0.125
0.125

Rate (ms)

25-50

100-200

Table 5.3.8-253: Radio Altitude Input Select Type 253

(ARINC 429 via dual IOC buses with DH discrete)

CHANNEL

429RX_1

CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data

Radio Altitude

Reference

6.2.29

Label

164

Sig. Bits

16

Range

±8192 FT

Signal Type

Basic

Resolution

0.125

Rate (ms)

25-50

CHANNEL

429RX_3

CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data

Radio Altitude

Reference

6.2.29

Label

164

Sig. Bits

16

Range

±8192 FT

Signal Type

Basic

Resolution

0.125

Rate (ms)

25-50

PIN FUNCTION

CONNECTION

PIN TYPE

CHANNEL DESIGNATION

REFERENCE

Polarity/Configuration

References

DH Discrete (Gnd)

J1-33

Input

GND_DISC_11

Gnd = Below DH
<not> Gnd = Above DH

6.6.14
4.2.7

Advertising